Cable design
Electrical data
Operating frequency:
|
≤ 18 GHz
|
Impedance:
|
50 Ω
|
Capacitance (pF/m):
|
87
|
Propagation velocity (% of c):
|
77
|
Signal delay (ns/m):
|
4,3
|
Insulation resistance dielectric:
|
≥ 100000000 MΩm
|
Operating Voltage (at sea level):
|
≤ 1.4 kVrms
|
Screening effectiveness:
|
≤ 90 dB (from 0.1 GHz up to 18 GHz)
|
Mechanical data
Weight (kg/100 m):
|
3,9
|
Static bending radius:
|
≥ 12 mm
|
Dynamic bending radius:
|
≥ 20 mm
|
Environmental data
Operation temperature:
|
-55 °C to +200 °C
|
Flame propagation test:
|
MIL-T-87104 § 4.6.4.8, FAR 25.869
|
Verified for lead-free soldering:
|
no
|
2011/65/EC (RoHS):
|
|
2006/1907/EC (REACH):
|
|
2002/96/EC (WEEE):
|
no special marking needed
|
2000/53/EC (ELV):
|
|
Nominal attenuation and power