Cable design
Electrical data
Operating frequency:
|
≤ 3 GHz
|
Impedance:
|
50 ± 2 Ω
|
Capacitance (pF/m):
|
97
|
Propagation velocity (% of c):
|
69
|
Signal delay (ns/m):
|
4,84
|
Insulation resistance dielectric:
|
≥ 100000000 MΩm
|
Operating Voltage (at sea level):
|
≤ .5 kVrms
|
Test voltage:
|
≤ 1 kVrms
|
Screening effectiveness:
|
≤ 40 dB (from 0.0001 GHz up to 1 GHz)
|
Mechanical data
Weight (kg/100 m):
|
0,84
|
Static bending radius:
|
≥ 10 mm
|
Repeated bending radius:
|
18 mm
|
Dynamic bending radius:
|
≥ 27 mm
|
Environmental data
Operation temperature:
|
-65 °C to +200 °C
|
Installation temperature:
|
-20 °C to +60 °C
|
Flame propagation test:
|
IEC 60332-3
|
2011/65/EC (RoHS):
|
|
2006/1907/EC (REACH):
|
|
Additional information
|
MIL reference: M17/93-RG178 and M17/93-00001
|
Nominal attenuation and power