ENVIROFLEX_316_D

Distributor Availability
Distributor In Stock
ECM USA 362 M
FC LANE 498 M
MOUSER 27 M
RICHARDSON 0 M *
Stock levels are subject to change
* Available with lead time
HUBER+SUHNER Factory Lead Time
Quantity Lead Time
< 5000  M 1 WEEK
> 5000  M 4 WEEKS
Item no.: 22512281
Description: RG316D/RD316 LSFH, 50 Ohm, 6 GHz, 105°C, ø3.16 mm, RADOX® jacket, Flame retardant, UL AWM style 3651, CPR qualified
Datasheet:
Declaration of performance / CPR:
Cable family: Enviroflex: LSFH alternatives to RG cables
Cable category: Flexible RF cable
Show suitable connectors: U4
Halogen free: Yes
Cable design
Electrical data
Operating frequency: ≤ 6 GHz
Impedance: 50 ± 2 Ω
Inner cond res DC (Ohm/km): 234
Outer cond. resistance DC (Ohm/km): 19
Capacitance (pF/m): 94,5
Propagation velocity (% of c): 70,1
Signal delay (ns/m): 4,72
Insulation resistance dielectric: ≥ 10000000 MΩm
Phase stability vs. temperature: 10000 ppm (-40 °C to +100 °C)
Phase stability vs. bending: c 0.7°/GHz (360°, radius 30 mm)
Bending test procedure: 360
Bending Radius: 30 mm
Operating Voltage (at sea level): ≤ 1.3 kVrms
Test voltage: ≤ 3 kVrms
Screening effectiveness: ≤ 70 dB (from 1 GHz up to 6 GHz)
Mechanical data
Weight (kg/100 m): 2,1
Static bending radius: ≥ 5 mm
Repeated bending radius: 30 mm (up to 30000 bendings)
Dynamic bending radius: ≥ 30 mm
Flex life test: MIL-T-81490 - §4.7.15 - prod. II - modified
Bending moment (Nm): 0,06
Abrasion test: MIL-T-81490 - §4.7.19 - prod. II - modified
Environmental data
Operation temperature: -40 °C to +105 °C
Installation temperature: -20 °C to +60 °C
Temperature rating: 105 °C
Cold bend test: MIL-C-17 § 4.8.19
Thermal stress test: IEC 61196-1 § 10.9
Ageing test: MIL-C-17 § 4.8.16
UV resistance test: IEC 60068-2-5, proc. C
Flame propagation test: EN 60332-1-2, UL 1581 § 1100, EN 50305, 9.1.2, FAR 25.869
Smoke emission test: EN 61034-2
Halogen test: IEC 60754
2011/65/EC (RoHS):
2006/1907/EC (REACH):
2002/96/EC (WEEE): no special marking needed
2000/53/EC (ELV):
Additional information
Railway certificates discontinued by end of 2017. Replacement type for railway: RADOX_RF_316_D.
Nominal attenuation and power