ENVIROFLEX_400

Distributor Availability
Distributor In Stock
ECM USA 238 M
RICHARDSON 0 M *
Stock levels are subject to change
* Available with lead time
HUBER+SUHNER Factory Lead Time
Quantity Lead Time
< 3000  M 1 WEEK
> 3000  M 4 WEEKS
Item no.: 22512280
Description: RG400 LSFH, 50 Ohm, 6 GHz, 105°C, ø5 mm, RADOX® jacket, Flame retardant, UL AWM style 3651, CPR qualified
Datasheet:
Cable family: Enviroflex: LSFH alternatives to RG cables
Cable category: Flexible RF cable
Show suitable connectors: U11
Halogen free: Yes
Cable design
Electrical data
Operating frequency: ≤ 6 GHz
Impedance: 50 ± 2 Ω
Inner cond res DC (Ohm/km): 31
Outer cond. resistance DC (Ohm/km): 8
Capacitance (pF/m): 94
Propagation velocity (% of c): 70,3
Signal delay (ns/m): 4,74
Insulation resistance dielectric: ≥ 10000000 MΩm
Phase stability vs. temperature: 10000 ppm (-40 °C to +100 °C)
Phase stability vs. bending: c 0.5°/GHz (360°, radius 40 mm)
Bending test procedure: 360
Bending Radius: 40 mm
Operating Voltage (at sea level): ≤ 2.5 kVrms
Test voltage: ≤ 5 kVrms
Screening effectiveness: ≤ 70 dB (from 0.001 GHz up to 6 GHz)
Mechanical data
Weight (kg/100 m): 6
Static bending radius: ≥ 10 mm
Repeated bending radius: 40 mm (up to 30000 bendings)
Dynamic bending radius: ≥ 40 mm
Bending moment (Nm): 0,26
Abrasion test: MIL-T-81490 - §4.7.19 - prod. II - modified
Environmental data
Operation temperature: -40 °C to +105 °C
Installation temperature: -20 °C to +60 °C
Temperature rating: 105 °C
Cold bend test: MIL-C-17 § 4.8.19
Thermal stress test: IEC 61196-1 § 10.9
Ageing test: MIL-C-17 § 4.8.16
UV resistance test: IEC 60068-2-5, proc. C
Flame propagation test: EN 60332-1-2, UL 1581 § 1100, IEC 60332-1
Smoke emission test: EN 61034-2
Halogen test: IEC 60754
Toxicity test: NF X 70-100
2011/65/EC (RoHS):
2006/1907/EC (REACH):
2002/96/EC (WEEE): no special marking needed
2000/53/EC (ELV):
Additional information
Railway certificates discontinued by end of 2017. Replacement type for railway: RADOX_RF_400.
Nominal attenuation and power