Electrical data
Impedance:
|
50 OHM
|
Nominal attenuation:
|
10 DB
|
Atten. deviation frame ±:
|
0,75 DB
|
Frequency max. (GHz):
|
6
|
Frequency Range (MHz):
|
0 GHz to 6 GHz
|
Return loss frame:
|
19,1 DB
|
Frequency Range 1:
|
0 GHz to 6 GHz
|
Return Loss[-dB]1:
|
19,1 DB
|
VSWR1:
|
1,25
|
Atten deviation range 1 ±:
|
0,75 DB
|
Power at room temp.:
|
50 W
|
Peak Power:
|
500 W, 5 µs pulse width, 0.050 % duty cycle
|
Average power:
|
50 W at 25 °C ambient temperature. Linearly derated to 10 W at 125 °C ambient temperature.
|
Power Rating Remarks:
|
Free airflow convection necessary to ensure power performance. Unit is unidirectional, therefore don't swap input with output (note: input is usually on the male side, otherwise follow instructions on the heatsink)
|
|
Mechanical data
Enviromental and general data
Operation temperature:
|
-65 °C to +125 °C
|
2011/65/EC (RoHS):
|
|
Interface 1
Interface 2
Ordering information
Available packagings:
|
Single
|