ajaxloader

ENVIROFLEX_B316_D

Item no.: 85087103
Datasheet:
Description: PE Foam - 50 Ohm - double screen
Cable family: Coaxial_high-flexible
Cable group: U4
Halogen free: Yes
Cable design
Centre cond. material: Steel, Copper+Silver plated
Centre cond. design: Strand-07
Centre cond. diam.: 0,54 mm
Dielectric material: SPE (Foamed Polyethylene)
Dielectric diameter: 1,5 mm
Outer cond. 1 material: Copper, Tin plated
Outer cond. 1 design: Braid
Outer cond. 1 coverage: 95 %
Outer cond. 1 diam.: 2 mm
Outer cond. 2 material: Copper, Tin plated
Outer cond. 2 design: Braid
Outer cond. 2 coverage: 85 %
Outer cond. 2 diam.: 2,4 mm
Jacket material: LSFH (modified polyethylene)
Jacket Colour: RAL 9005 - bk
Jacket diameter: 3,16 mm
Jacket tolerance: 0,1 mm
Electrical data
Operating frequency (GHz): 6
Impedance: 50 OHM
Impedance tolerance ±: 2 OHM
Inner cond res DC (Ohm/km): 234
Outer cond. resistance DC (Ohm/km): 19
Capacitance (pF/m): 94,5
Propagation velocity (% of c): 71
Signal delay (ns/m): 4,7
Insulation resistance dielectric (MOhm/m): 10.000.000
Operating Voltage at Sea Level (kVrms): 1,3 KV
Test voltage, 50 Hz, 1 min (kVrms): 3
Screen frequency min. (GHz): 1
Screen frequency max. (GHz): 6
Screen effectiveness: 60 DB
Mechanical data
Weight (kg/100 m): 1,9
Static bend radius: 5 mm
Number of max. Bendings: 30.000
Repeated bending radius: 30 mm
Dynamic bending radius: 30 mm
Bending moment (Nm): 0,06
Enviromental and general data
Operating temp. min.: -40,0 °C
Operating temp. max.: 85 °C
Installation temp. min.: -20 °C
Installation temp. max.: 60 °C
Cold bend test: MIL-C-17 § 4.8.19
Thermal stress test: IEC 61196-1 § 10.9
Flame propagation test: IEC 60332-1
2011/65/EC (RoHS): compliant
2006/1907/EC (REACH): compliant
Nominal attenuation and power