3401.17.0057-EX

Item no.: 85019174
Datasheet:
Description: GDT technology up to 1.0 GHz
Highlights: Self-extinguishing Semper functionality
Broad-band design
DC continuity for remote powering
The protector can also be installed reversely
Replaceable GDT unit 9071.99.0647, (230 V) included
Outline drawing:
Mounting instruction:
Picture:
Product configuration
Port 1 (main path, unprot. side): N plug (male)
Port 2 (main path, prot. side): N jack (female)
Bulkhead mounting (mounting hole): 12
Side of bulkhead: protected side
Electrical data
Frequency range: 0 MHz to 1000 MHz
Impedance: 50 OHM
DC Supply voltage (<=): 48 V
DC current (<=): 2,5 A
Surge current handling capability: 30 single / 20 multiple single kA (test pulse 8/20 µs)
Residual pulse energy: 350 µJ typically (test pulse 4 kV 1.2/50 µs / 2 kA 8/20 µs) main path - protected side
Mechanical data
Number of matings: 500
Weight: 114 g
Enviromental and general data
Operation temperature: -40 °C to +85 °C
IP rating: IP65
2011/65/EC (RoHS): compliant acc. Annex III
Material data