ajaxloader

5903_716-50-1/000_NE

Item no.: 84060159
Datasheet:
Description: Standard Attenuator, High Power
Outline drawing:
Picture:
Type
Interface 1: 7/16
Gender 1: plug (male)
Interface 2: 7/16
Gender 2: jack (female)
Interface standard 1: IEC 60169-4_CECC 22190_DIN 47223_VG 95250
Interface standard 2: IEC 60169-4_CECC 22190_DIN 47223_VG 95250
Electrical data
Impedance: 50 OHM
Nominal attenuation: 3 DB
Atten. deviation frame ±: 0,5 DB
Frequency max. (GHz): 2,7
Frequency min. (GHz): 0
Return loss frame: 16,5 DB
Interface freq. min. (GHz): 0
Interface freq. max. (GHz): 1,5
Return loss band 1: 19,1 DB
VSWR range 1: 1,25
Frequency min. 2 (GHz): 1,5
Frequency max. 2 (GHz): 2,7
Return loss band 2: 16,5 DB
VSWR range 2: 1,35
Atten deviation range 1 ±: 0,5 DB
Atten deviation range 2 ±: 0,5 DB
Average power: 100 W
Average power to (ambient temp.): 25 °C
Power linearly derated to: 20 W
Power linearly derated at (ambient temp.): 125 °C
Peak power: 1.000 W
Power Rating Remarks: Free airflow convection necessary to ensure power "performance". Unit is unidirectional, therefore don't swap input with output (note: input is usually on the male side, otherwise follow instructions on the heatsink)
Duty cycle: 0,5 %
Puls Width (µs): 5
Enviromental and general data
Operating temp. min.: -55,0 °C
Operating temp. max.: 125,0 °C
2011/65/EC (RoHS): compliant
Mechanical data
Weight: 1,27 kg
Interface 1
Interface 2
Ordering information
Available packagings: Single